InfraGuard

CVE-2026-104133

OpenEMR: Missing authorization in DORN `compendium_install.php` — non-admin destructive lab-compendium reinstall

7.1 CVSS 3.1EPSS 0.5%

원문 설명

OpenEMR is a free and open source electronic health records and medical practice management application. Prior to 8.3.0, interface/modules/custom_modules/oe-module-dorn/public/compendium_install.php checks authentication and CSRF but does not require the admin/users ACL enforced by sibling DORN administration scripts. When the DORN module is enabled, a low-privilege authenticated user can supply a labGuid that causes LabCompendiumInstall::uninstall() to delete detail and result procedure types and deactivate order types before the reinstall step. The action can corrupt lab-ordering configuration and require an administrator to restore the compendium. This issue is fixed in version 8.3.0.

영향받는 소프트웨어

상세

공개일
2026-11-05
최종 수정
2026-11-10
CVSS 벡터
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L
CWE
CWE-862
EPSS(30일 내 악용 확률)
0.47% (백분위 41)