OpenEMR: Missing authorization in DORN `compendium_install.php` — non-admin destructive lab-compendium reinstall

7.1 CVSS 3.1EPSS 0.5%

原文の説明

OpenEMR is a free and open source electronic health records and medical practice management application. Prior to 8.3.0, interface/modules/custom_modules/oe-module-dorn/public/compendium_install.php checks authentication and CSRF but does not require the admin/users ACL enforced by sibling DORN administration scripts. When the DORN module is enabled, a low-privilege authenticated user can supply a labGuid that causes LabCompendiumInstall::uninstall() to delete detail and result procedure types and deactivate order types before the reinstall step. The action can corrupt lab-ordering configuration and require an administrator to restore the compendium. This issue is fixed in version 8.3.0.

影響を受けるソフトウェア

詳細

公開日
2026-11-05
最終更新
2026-11-10
CVSS ベクター
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L
CWE
CWE-862
EPSS(30日以内の悪用確率)
0.47% (パーセンタイル 41)