InfraGuard

CVE-2026-77072

n8n before 1.123.69 Stored XSS via Form Completion Page

8.4 CVSS 4.0EPSS 0.3%

Исходное описание

n8n before 1.123.69, 2.33.4, and 2.34.1 contains a stored cross-site scripting vulnerability in the Form node's completion page. The completion page applied its sandboxing Content-Security-Policy only when respondWith was not set to 'redirect', but responseText was always rendered as raw HTML. An authenticated member could set respondWith to 'redirect' via an expression while keeping responseText populated, causing the completion page to serve unsanitized HTML and script from the n8n origin. Any visitor who submitted the resulting public form would have that script execute same-origin with their session.

Затронутое ПО

Подробности

Опубликовано
2026-08-20
Последнее изменение
2026-09-01
Вектор CVSS
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:
CWE
CWE-79
EPSS (вероятность эксплуатации в течение 30 дней)
0.31% (перцентиль 24)

Ссылки

Отслеживайте эти версии на своих серверах

InfraGuard собирает версии установленного ПО со всех серверов и отмечает версии с известными уязвимостями. Self-hosted — данные не покидают вашу сеть.

Еженедельный дайджест эксплуатируемых уязвимостей

Новые записи KEV, важные для self-hosted серверов, раз в неделю. Никаких других писем.