원문 설명
A flaw was found in samba. The Samba smbd file server must map Windows group identities (SIDs) into unix group ids (gids). The code that performs this had a flaw that could allow it to read data beyond the end of the array in the case where a negative cache entry had been added to the mapping cache. This could cause the calling code to return those values into the process token that stores the group membership for a user. The highest threat from this vulnerability is to data confidentiality and integrity.
영향받는 소프트웨어
- Samba ≥ 4.13.0 < 4.13.8≥ 3.6.0 < 4.12.15≥ 4.14.0 < 4.14.4 수정 버전: 4.13.8, 4.12.15, 4.14.4 정확 일치
상세
- 공개일
- 2021-05-05
- 최종 수정
- 2026-06-17
- CVSS 벡터
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N- CWE
- CWE-125
- EPSS(30일 내 악용 확률)
- 1.62% (백분위 76)
참고 자료
- cve.org/CVE-2021-20254
- nvd.nist.gov/vuln/detail/CVE-2021-20254
- bugzilla.redhat.com/show_bug.cgi?id=1949442
- lists.debian.org/debian-lts-announce/2021/05/msg00023.html
- lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/3...
- lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/Z...
- security.gentoo.org/glsa/202105-22
- security.netapp.com/advisory/ntap-20210430-0001/
- www.samba.org/samba/security/CVE-2021-20254.html
내 서버의 버전을 직접 추적하세요
InfraGuard 는 모든 서버에 설치된 소프트웨어 버전을 수집하고, 알려진 취약점이 있는 버전을 알려 줍니다. 자체 호스팅이라 데이터가 내 네트워크를 벗어나지 않습니다.
이 제품은 NVD API 데이터를 사용하지만 NVD 의 보증이나 인증을 받은 것은 아닙니다. CVE® 는 The MITRE Corporation 의 등록 상표이며, CVE 레코드는 CVE Program 이용 약관에 따라 사용합니다.