InfraGuard

CVE-2026-116574

FreeSWITCH: Off-by-one heap write in core XML serialization of four-byte UTF-8 sequences

5.9 CVSS 3.1EPSS 0.4%

原文の説明

FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.2, switch_xml_ampencode() reserved only ten bytes for the widest numeric character reference produced from a four-byte UTF-8 sequence, omitting space for the terminating NUL. When remote-supplied text was serialized at the exact buffer-growth boundary, the terminator wrote one byte beyond the heap allocation. Reachable surfaces include mod_xml_cdr, conference and formatted CDR XML, XML Event Socket output, and XML API output that serializes caller-controlled values. The fixed zero-byte write can abort the process or truncate an adjacent object, while remote code execution has not been demonstrated. This issue is fixed in version 1.11.2.

影響を受けるソフトウェア

詳細

公開日
2026-11-06
最終更新
2026-11-10
CVSS ベクター
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H
CWE
CWE-193, CWE-787
EPSS(30日以内の悪用確率)
0.38% (パーセンタイル 32)

参考資料

自社サーバーでこれらのバージョンを追跡

InfraGuard はすべてのサーバーからインストール済みソフトウェアのバージョンを収集し、既知の脆弱性があるものを通知します。セルフホスト型なので、データがネットワーク外に出ることはありません。

悪用された脆弱性の週刊ダイジェスト

セルフホスト型サーバーに関係する KEV の追加情報を週1回お届けします。それ以外のメールは送りません。

本製品は NVD API のデータを使用していますが、NVD による承認または認定を受けたものではありません。CVE® は The MITRE Corporation の登録商標です。CVE レコードは CVE Program の利用規約に基づいて使用しています。