Description d’origine
A user who can open a fork pull request can place workflow content with a shared run-level concurrency group into a Gitea Actions run that is awaiting approval. When a later run in that group cancels the blocked job, the run becomes terminal while still marked as needing approval. If a maintainer later approves the run, Gitea passed the already-cancelled job back through concurrency preparation, set it to waiting, and made it claimable by a matching runner, executing fork-controlled workflow code. Exploitation requires the maintainer's later approval action, Actions to be enabled, and a runner that accepts the repository's jobs.
Logiciels concernés
- Gitea < 28.0.0 Corrigé dans: 28.0.0 correspondance exacte
Détails
- Publication
- 2026-10-06
- Dernière modification
- 2026-10-13
- Vecteur CVSS
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H- CWE
- CWE-841
- EPSS (probabilité d’exploitation à 30 jours)
- 0.33% (percentile 27)