Description d’origine
When asked to both use a `.netrc` file for credentials and to follow HTTP redirects, curl could leak the password used for the first host to the followed-to host under certain circumstances. This flaw only manifests itself if the netrc file has an entry that matches the redirect target hostname but the entry either omits just the password or omits both login and password.
Logiciels concernés
- curl ≥ 7.76.0 < 8.11.1 Corrigé dans: 8.11.1 correspondance exacte
Détails
- Publication
- 2024-12-11
- Dernière modification
- 2026-10-15
- Vecteur CVSS
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:N/A:N- EPSS (probabilité d’exploitation à 30 jours)
- 1.97% (percentile 81)
Références
- cve.org/CVE-2024-11053
- nvd.nist.gov/vuln/detail/CVE-2024-11053
- curl.se/docs/CVE-2024-11053.html
- curl.se/docs/CVE-2024-11053.json
- hackerone.com/reports/2829063
- www.openwall.com/lists/oss-security/2024/12/11/1
- security.netapp.com/advisory/ntap-20250124-0012/
- security.netapp.com/advisory/ntap-20250131-0003/
- security.netapp.com/advisory/ntap-20250131-0004/
- cert-portal.siemens.com/productcert/html/ssa-089022.html
- cert-portal.siemens.com/productcert/html/ssa-212953.html
- cert-portal.siemens.com/productcert/html/ssa-398330.html
Suivez ces versions sur vos propres serveurs
InfraGuard collecte les versions logicielles installées sur chaque serveur et signale celles qui présentent des vulnérabilités connues. Auto-hébergé : rien ne quitte votre réseau.
Ce produit utilise des données de l’API du NVD, mais n’est ni approuvé ni certifié par le NVD. CVE® est une marque déposée de The MITRE Corporation ; les enregistrements CVE sont utilisés conformément aux conditions d’utilisation du CVE Program.