InfraGuard

CVE-2026-129525

Gitea pull request disclosure to members with access to issues only

5.4 CVSS 3.1EPSS 0.2%

Descripción original

Several endpoints that work on both issues and pull requests did not check which of the two the addressed item is. A user who can read a repository's issues but not its pull requests could read pull request data through the issue sub-resources of the API (timeline, attachments, labels, subscriptions, tracked times and reactions), and list pull requests through the repository's issue search and milestone pages; the same applied in the other direction. These endpoints now check read access to the unit the item belongs to. The API endpoints were fixed in 28.2.0 and 28.3.0, the search and milestone pages in 28.4.0.

Software afectado

Detalles

Publicación
2026-11-16
Última modificación
2026-11-17
Vector CVSS
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
CWE
CWE-862
EPSS (probabilidad de explotación en 30 días)
0.17% (percentil 7)

Referencias

Controla estas versiones en tus propios servidores

InfraGuard recopila las versiones de software instaladas en cada servidor y señala las que tienen vulnerabilidades conocidas. Autoalojado: nada sale de tu red.

Resumen semanal de vulnerabilidades explotadas

Las incorporaciones a KEV relevantes para servidores autoalojados, una vez por semana. Ningún otro correo.

Este producto utiliza datos de la API del NVD, pero no está avalado ni certificado por el NVD. CVE® es una marca registrada de The MITRE Corporation; los registros CVE se utilizan conforme a los Términos de uso del CVE Program.