InfraGuard

CVE-2026-116779

FreeSWITCH: Inbound SIP MESSAGE can select the api chat proto and run FreeSWITCH API commands

9.8 CVSS 3.1 Exploited in the wildEPSS 2.5%

What is wrong

Inbound SIP MESSAGE parsing allows peers to select the API chat protocol and run FreeSWITCH API commands with the daemon's privileges. This flaw enables attackers to perform credential and configuration disclosure, arbitrary call control, and remote command execution.

Who is affected

This vulnerability affects FreeSWITCH versions prior to 1.11.3 with inbound chat enabled, including standard installations using stock internal and external profiles.

What to do

Upgrade FreeSWITCH to version 1.11.3 or later to fix the issue.

Original description

FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.3, sofia_presence_handle_sip_i_message() split the To user of an inbound SIP MESSAGE on a plus sign and treated the left side as a chat protocol selector. Selecting the api chat proto reached switch_api_execute(), allowing a peer whose MESSAGE was accepted to run FreeSWITCH API commands, including operating-system command sinks, with the daemon's privileges. Inbound chat is enabled on the stock internal and external profiles, and any authenticated profile account is sufficient; stock directory users without password material can also remove that barrier in affected configurations. The flaw permits configuration and credential disclosure, arbitrary call control, and command execution, and exploitation has been observed in the wild. This issue is fixed in version 1.11.3.

Known exploited (CISA KEV)

Added to KEV
2026-11-09
Remediation due (US federal)
2026-11-12
Ransomware use
Unknown
Required action
Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

Affected software

Details

Published
2026-11-05
Last modified
2026-11-10
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CWE
CWE-77, CWE-78, CWE-749
EPSS (30-day exploit probability)
2.47% (percentile 85)

References

Track these versions on your own servers

InfraGuard collects installed software versions from every server and flags the ones with known vulnerabilities. Self-hosted — nothing leaves your network.

Weekly exploited-vulnerability digest

The KEV additions that matter for self-hosted servers, once a week. No other mail.

This product uses data from the NVD API but is not endorsed or certified by the NVD. CVE® is a registered trademark of The MITRE Corporation; CVE records are used under the CVE Program Terms of Use.