InfraGuard

CVE-2026-100684

Budibase Server 3.41.0 before 3.45.0 Authentication Bypass via OIDC

9.2 CVSS 4.0EPSS 0.4%

Originalbeschreibung

Budibase versions 3.41.0 before 3.45.0 contain an authentication bypass in the OIDC/SSO login path of @budibase/server. In sso.authenticate, when no existing user matches the incoming SSO subject, the server looks up pending user invites by the IdP-asserted email address alone — without validating an invite code and without an email_verified check (the email_verified gate protects only the existing-account lookup). An attacker who can register at an IdP that the tenant trusts for OIDC and assert a victim's invited email address (even with email_verified=false) claims the pending invite and inherits all of its granted privileges, including builder and admin.global, with no admin exclusion. This results in takeover of the invited principal and, for admin invites, full tenant compromise (access to all apps, datasources including production credentials, and automations); the invite is consumed, denying onboarding to the legitimate invitee.

Betroffene Software

Details

Veröffentlicht
2026-09-26
Zuletzt geändert
2026-10-09
CVSS-Vektor
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CWE
CWE-287
EPSS (Ausnutzungswahrscheinlichkeit in 30 Tagen)
0.42% (Perzentil 37)

Referenzen

Verfolgen Sie diese Versionen auf Ihren eigenen Servern

InfraGuard erfasst die installierten Softwareversionen auf jedem Server und markiert diejenigen mit bekannten Schwachstellen. Self-Hosted – nichts verlässt Ihr Netzwerk.

Wöchentlicher Digest ausgenutzter Schwachstellen

Die für Self-Hosted-Server relevanten KEV-Neuzugänge, einmal pro Woche. Keine weiteren E-Mails.

Dieses Produkt verwendet Daten der NVD-API, ist jedoch nicht von der NVD empfohlen oder zertifiziert. CVE® ist eine eingetragene Marke von The MITRE Corporation; CVE-Datensätze werden gemäß den Nutzungsbedingungen des CVE Program verwendet.